Abstract

CARS spectra of NH3 have been obtained from a commercial catalytic ammonia oxidation plant operating at ∼10 atmospheres (absolute) and 250°C. A purpose-designed ruggedized CARS spectrometer—incorporating a novel dye laser, remote control, and fiber optic signal transfer—is described. A new and simple technique for CARS concentration analysis using polarized beams gave a precision of 5.9% for NH3 from single-shot spectra under laboratory conditions. Unfortunately, severe beam steering problems were encountered in the full-scale plant; this prevented a quantitative analysis of the spectra obtained. The origins of this problem together with suggestions for overcoming or reducing its effect are given.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.