Abstract
Screening for infectious diseases of cattle using milk from the dairy herd improvement (DHI) sampling process is very convenient. However, when samples from shared milk meters are used, carryover of antibodies or other diagnostic targets can complicate the interpretation of the diagnostic test results for diseases, including bovine leukosis. The objectives of this study were (1) to assess the potential for carryover of antibodies against bovine leukemia virus (BLV) in milk samples obtained from shared meters, and (2) to determine if adjustment of the diagnostic test cut-off value would improve the test characteristics for meter-collected milk ELISA results. Eight dairy farms were randomly selected from herds with a wide range of BLV prevalence levels in Prince Edward Island, Canada. Within each chosen farm, 2 to 4milk meters were randomly selected. During the routine procedures of DHI sampling, 2 simultaneous milk samples, 1 hand-collected at the beginning of milking (after udder preparation) and the other from the corresponding milk meter, were taken from all lactating cows (n=236) that were milked at the selected meters (n=26). The sequence of cows using each meter was recorded. All samples were tested for BLV antibodies using a commercial indirect ELISA. Antibody carryover potential was assessed in meter-collected samples which were preceded by other cows using the same meters. Applying the hand-collected sample results as our reference standard, a new cut-off was defined for meter-collected samples to optimize the test characteristics. At the standard cut-off value of the diagnostic test, 110 (46.6%) of the hand-collected and 136 (57.6%) of the meter-collected samples were positive. For low-titer cows (e.g., true negatives), the likelihood of antibody carryover significantly increased as the titer of preceding cows increased, whereas this change was not substantial for high-titer cows. The odds of obtaining false diagnoses in meter-positive samples became larger with increase in the titer of preceding cows. A suspicious category for meter ELISA results was defined, and a retest was recommended for the cows falling into this category. This strategy effectively assisted in reducing the number of consequent false-positive results. When DHI-collected samples are used, carryover can affect the interpretation of dichotomous test results and may require adjustment of assay cut-off values.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.