Abstract

This paper compares pulsating and rotating vector carrier signal injection for self-sensing (or sensorless) control of PM synchronous machines. The main focus of the study is evaluation of estimation errors due to the physical non-ideal attributes of both the machine and the inverter. Initial position and magnet polarity estimation are analyzed as well. Transient response and signal processing for both techniques is discussed for completeness. The theoretical analysis is supported by experimental and simulation evidence obtained using interior PM synchronous machines.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.