Abstract

We present a new technique for carotid artery reconstruction using a modified bifurcated saphenous vein graft in a patient with a malignant neck tumor. This technique can optimize the size match between the SVG and common carotid artery, as well as the internal and external carotid arteries. Post operative computed tomography performed a year after the operation demonstrated excellent graft alignment and patent carotid arteries.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.