Abstract
We compare the clinical efficacy of two approaches for balloon aortic valvuloplasty (BAV) in infants with critical aortic valve stenosis. The approaches were through the carotid artery and the femoral artery. Eight catheterizations for BAV were performed in seven consecutive patients with critical aortic stenosis: four BAVs were approached through the femoral artery and four through the right common carotid artery. We inserted a 5F sheath into the right common carotid artery by a cutdown procedure; after BAV the sheath was removed and the carotid arteriotomy sutured with 7-0 monofilament. Two cases in which the femoral artery approach was used resulted in failure to perform BAV; two cases had complications. All four cases with the carotid artery approach were successful, with no complications; aortography performed 3 months after one balloon valvuloplasty revealed a smooth, unobstructed right carotid artery. Use of the carotid artery approach may reduce serious complications with BAV and offers quicker, easier maneuvering in infants and neonates with critical aortic valve stenosis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.