Abstract

IntroductionThe small size of a nidus and the extensive sclerosis around it often make it difficult to identify tumors from the surrounding normal bone by fluoroscopy, and a large amount of bone resection might be required to secure complete removal during osteoid osteoma surgery. In this report, we present the first case of radiographically invisible osteoid osteoma that was successfully resected under a robotic C-arm cone-beam computed tomography (CBCT) imaging system. Presentation of caseA 14-year-old boy presented with persistent pain around the left knee joint was diagnosed with osteoid osteoma of the left distal femur. Since the tumor was not detectable by intraoperative fluoroscopy, a CBCT system was used for guidance during an open tumor resection. For a less invasive surgery, we repurposed the dilator and retractor of the microendoscopic discectomy (MED) system and resected the tumor using the wider trephine tips for bone biopsy. At the final follow-up one year later, the function of the afflicted limb was normal with no complaint of any symptoms. Plain radiograph at the final follow-up showed new bone formation completely filling the bone defect, without local recurrence. DiscussionCBCT allowed for clear intraoperative visualization of the osteoid osteoma, thereby promising a secure resection and less invasive osteoid osteoma treatment. Furthermore, the repurposed use of the dilator and retractor of the MED system as well as the wider trephine tips for bone biopsy made the procedure less invasive. ConclusionCBCT-guided minimally invasive open excision surgery could be a useful option for the management of radiographically invisible osteoid osteoma.

Highlights

  • The small size of a nidus and the extensive sclerosis around it often make it difficult to identify tumors from the surrounding normal bone by fluoroscopy, and a large amount of bone resection might be required to secure complete removal during osteoid osteoma surgery

  • Osteoid osteoma is a benign bone tumor that occurs in children and adolescents, and causes severe pain [1,2]

  • We report a radiographically invisible osteoid osteoma of the distal femur that was successfully resected under robotic C-arm cone-beam computed tomography (CBCT), which is a multi-axis C-arm radiography system and provides CT-like images intraoperatively

Read more

Summary

INTRODUCTION

The small size of a nidus and the extensive sclerosis around it often make it difficult to identify tumors from the surrounding normal bone by fluoroscopy, and a large amount of bone resection might be required to secure complete removal during osteoid osteoma surgery. For a less invasive surgery, we repurposed the dilator and retractor of the microendoscopic discectomy (MED) system and resected the tumor using the wider trephine tips for bone biopsy. The repurposed use of the dilator and retractor of the MED system as well as the wider trephine tips for bone biopsy made the procedure less invasive. CONCLUSION: CBCT-guided minimally invasive open excision surgery could be a useful option for the management of radiographically invisible osteoid osteoma

Introduction
Presentation of case
Discussion
Conclusion
Findings
Ethical approval
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.