Abstract

Near-infrared imaging (NIRI) has been proposed as an alternative to radiographs and uses nonionizing radiation in the near-infrared spectrum to differentially scatter light off tooth surfaces and generate images allowing interproximal caries detection. The new iTero 5D Element Scanner (Align Technology, Santa Clara, Calif) has integrated NIRI capture and viewing technology but has not been specifically studied in a pediatric population. Therefore, this study aimed to assess clinicians' abilities to detect and characterize caries in pediatric patients using this instrument. Bitewing (BW) radiographs and an intraoral scan were captured on 17 pediatric patients (344 surfaces were analyzed). Data were randomized and graded by 5 calibrated clinicians individually with 2 different rounds of grading. The reliability of lesion characterization (ie, grade) among examiners was poor to fair in both systems, whereas the reliability of caries detection was moderate. Both systems had a high specificity and low sensitivity. The reliability of the characterization of the combined dataset was moderate to substantial, whereas, for detection, it was substantial. When using either BW or NIRI analysis, reliability is relatively poor, and clinicians are more likely to correctly identify a healthy tooth surface when compared with a carious surface. There is a small difference in error rate between BW and NIRI systems that is not likely to be clinically significant. When NIRI and BW data are combined, clinician agreement for both lesion characterization and detection increases significantly.