Abstract

Infections of cardiovascular implantable electric devices (CIED) are a burden on patients and healthcare systems and should be prevented. The most frequent pathogens are coagulase-negative staphylococci and Staphylococcus aureus. The most important risk factors for CIED infections are diabetes mellitus, renal and heart failure, corticosteroid use, oral anticoagulation, fever within 24 hours before the procedure and leucocytosis, implantable cardioverter defibrillator compared with pacemaker, especially in the case of Staphylococcus aureus bacteraemia, lack of antibiotic prophylaxis, and postoperative haematoma and other wound complications. Other important risk factors are history of prior procedures and previous CIED infections, number of leads, use of povidone-iodine compared with chlorhexidine-alcohol, and centres and operators with a low volume of implants. To prevent CIED infections, patients undergoing CIED procedures and appropriate devices should be carefully selected, and interventions should be performed by trained operators. Antibiotic prophylaxis should be administered, and skin antisepsis should be done with chlorhexidine-alcohol. Oral anticoagulation should be continued during CIED procedures in high-risk patients for thromboembolism, instead of bridging with heparin. Early reintervention in cases of haematoma or lead dislodgement should be avoided. The implementation of infection prevention programmes reduces infection rates. More randomised controlled studies are needed to evaluate prevention strategies, especially skin preparation and antibiotic prophylaxis with glycopeptides.

Highlights

  • Infections of cardiovascular implantable electronic devices (CIEDs) can affect the generator pocket site only, the leads and valves resulting in cardiovascular implantable electric devices (CIED) infective endocarditis, or both

  • The most important risk factors for CIED infections are diabetes mellitus, renal and heart failure, corticosteroid use, oral anticoagulation, fever within 24 hours before the procedure and leucocytosis, implantable cardioverter defibrillator compared with pacemaker, especially in the case of Staphylococcus aureus bacteraemia, lack of antibiotic prophylaxis, and postoperative haematoma and other wound complications

  • Other important risk factors are history of prior procedures and previous CIED infections, number of leads, use of povidone-iodine compared with chlorhexidine-alcohol, and centres and operators with a low volume of implants

Read more

Summary

Summary

Infections of cardiovascular implantable electric devices (CIED) are a burden on patients and healthcare systems and should be prevented. The most important risk factors for CIED infections are diabetes mellitus, renal and heart failure, corticosteroid use, oral anticoagulation, fever within 24 hours before the procedure and leucocytosis, implantable cardioverter defibrillator compared with pacemaker, especially in the case of Staphylococcus aureus bacteraemia, lack of antibiotic prophylaxis, and postoperative haematoma and other wound complications. Other important risk factors are history of prior procedures and previous CIED infections, number of leads, use of povidone-iodine compared with chlorhexidine-alcohol, and centres and operators with a low volume of implants. To prevent CIED infections, patients undergoing CIED procedures and appropriate devices should be carefully selected, and interventions should be performed by trained operators.

Introduction
Risk factors for CIED infections
Prevention of CIED infections
Risk factor
Diabetes mellitus Heart disease Simultaneous other procedure Two leads
More than one procedure
Physician with a low volume of implants
ICD vs PM
Areas of uncertainty
Findings
Infection prevention programmes