Abstract
BackgroundRetransfusion of the patient's own blood during surgery is used to reduce the need for allogenic blood transfusion. It has however been found that this blood contains lipid particles, which form emboli in different organs if the blood is retransfused on the arterial side. In this study, we tested whether retransfusion of blood containing lipid micro-particles on the venous side in a porcine model will give hemodynamic effects.MethodsSeven adult pigs were used. A shed blood surrogate containing 400 ml diluted blood and 5 ml radioactive triolein was produced to generate a lipid embolic load. The shed blood surrogate was rapidly (<2 minutes) retransfused from a transfusion bag to the right atrium under general anesthesia. The animals' arterial, pulmonary, right and left atrial pressure were monitored, together with cardiac output and deadspace. At the end of the experiment, an increase in cardiac output and pulmonary pressure was pharmacologically induced to try to flush out lipid particles from the lungs.ResultsA more than 30-fold increase in pulmonary vascular resistance was observed, with subsequent increase in pulmonary artery pressure, and decrease in cardiac output and arterial pressure. This response was transient, but was followed by a smaller, persistent increase in pulmonary vascular resistance. Only a small portion of the infused triolein passed the lungs, and only a small fraction could be recirculated by increasing cardiac output and pulmonary pressure.ConclusionInfusion of blood containing lipid micro-emboli on the venous side leads to acute, severe hemodynamic responses that can be life threatening. Lipid particles will be trapped in the lungs, leading to persistent effects on the pulmonary vascular resistance.
Highlights
Retransfusion of the patient's own blood during surgery is used to reduce the need for allogenic blood transfusion
In this study we investigated the effect of re-transfusion of blood containing lipid micro-emboli on the venous side, in terms of hemodynamic and respiratory effects, as well as the lipid removal capacity of the lungs in a porcine model
The infusion led to total circulatory collapse within 10 minutes due to acute right heart failure, despite attempts to reverse the condition with epinephrine
Summary
Retransfusion of the patient's own blood during surgery is used to reduce the need for allogenic blood transfusion. We tested whether retransfusion of blood containing lipid micro-particles on the venous side in a porcine model will give hemodynamic effects. Autotransfusion of blood is used in surgical procedures to reduce the need for allogenic blood transfusion. Adverse effects of heterologous transfusions have recently been highlighted [1]. It (page number not for citation purposes). Blood conservation strategies are employed routinely in several surgical procedures. For example, blood lost in the pericardium or pleurae is routinely retransfused directly to the patient via the heart-lung machine.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.