Abstract

We compared high frequency ventilation (HFV) to conventional mechanical ventilation (CMV) under normoxic and normocapnic condition in surfactant depleted rabbits with bilateral pneumothoraces. We hypothesized that lower airway pressures would be required with HFV under these conditions. We applied CMV and HFV in 8 anaesthetized rabbits with a prototype ventilator at frequencies of 30, 100, 200, and 300 cycles/min. A positive end-expiratory pressure (PEEP) just below the pressure sufficient to open the air leak from the pneumothoraces was applied at all frequencies. Airway pressures, gas exchange, heart rate, and mean arterial pressure were recorded. Peak airway pressure decreased significantly from 2.50 to 2.10 kPa when the frequency of ventilation was increased from 30 to 300 cycles/min. There were no significant changes in mean airway pressure, PaO2, arterial pH, heart rate, and mean arterial pressure when HFV was compared to CMV. In conclusion, during HFV peak airway pressures measured at the mouth were decreased. Our ability to maintain adequate gas exchange in the face of ongoing pulmonary air leaks may reflect lower alveolar pressures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.