Abstract
Pregnancy with history of peripartum cardiomyopathy, residual left ventricular dysfunction is associated with high maternal and neonatal morbidity and mortality. Remote monitoring of pulmonary artery pressure and vital signs have been utilized in clinical settings to manage select patients with heart failure. However, data of using these systems to aid clinical management in pregnancy remains unexplored. To our knowledge, this case report is the first to describe successful management of a 31-year-old pregnant patient with history of peripartum cardiomyopathy, severe left ventricular dysfunction and pulmonary embolism using the CardioMEMS device throughout pregnancy. CardioMEMS system provided continuous remote hemodynamic monitoring during pregnancy, aiding in the management of this high-risk patient. The device’s ability to provide real-time data allowed for correlation between symptoms and hemodynamics, allowing for prompt adjustments in treatment, ensuring stability throughout the pregnancy. This patient was able to avoid hospital admissions and successfully deliver a healthy baby at term via vaginal delivery. This report highlights the potential benefits of utilizing CardioMEMS in clinical management of such patients.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: European Journal of Obstetrics & Gynecology and Reproductive Biology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.