Abstract

ABSTRACTThis study evaluated the feasibility of cardiodynamicsgram (CDG) for monitoring the cardiac functions of athletes and exercisers. CDG could provide an effective, simple, and economical tool for exercise training. Seventeen middle-distance race athletes aged 14–28 years old were recruited. CDG tests and blood test including creatine kinase (CK), CK-MB isoenzyme, and high-sensitivity troponin I (hsTnI) were performed before a high-intensity prolonged training, as well as 2 and 14 h after training, respectively. The CDG test result was unsatisfactory when the CK test result was used as standard. However, the accuracy of CDG test was about 80% when CK-MB and hsTnI were used as standards. Thus, CDG offers a noninvasive, simple, and economical approach for monitoring the cardiac function of athletes and exercisers during exercise training. Nonetheless, the applicability of CDG needs further investigation.