Abstract

A prospective clinical trial was conducted for patients undergoing cardiac sparing (CS) whole lung irradiation (WLI) using intensity modulated radiation therapy (IMRT). The 3 trial aims were (1) to demonstrate the feasibility of CS IMRT with real-time central quality control; (2) to determine the dosimetric advantages of WLI using IMRT compared with standard anteroposterior (AP) techniques; and (3) to determine acute tolerance and short-term efficacy after a protocol-mandated minimum 2-year follow-up for all patients. All patients underwent a 3-dimensional chest computed tomography scan and a contrast-enhanced 4-dimensional (4D) gated chest computed tomography scan using a standard gating device. The clinical target volume was the entire bilateral 3-dimensional lung volume, and the internal target volume was the 4D minimum intensity projection of both lungs. The internal target volume was expanded by 1cm to get the planning target volume. All target volumes, cardiac contours, and treatment plans were centrally reviewed before treatment. The different cardiac volumes receiving percentages of prescribed radiation therapy (RT) doses on AP and IMRT WLI plans were estimated and compared. The target 20 patients were accrued in 2years. Median RT dose was 15Gy. Real-time central quality assurance review and plan preapproval were obtained for all patients. WLI using IMRT was feasible in all patients. Compared with standard AP WLI, CS IMRT resulted in a statistically significant reduction in radiation doses to the whole heart, atria, ventricles, and coronaries. One child developed cardiac dysfunction and pulmonary restrictive disease 5.5years after CS IMRT (15Gy) and doxorubicin (375mg/m2). The 2- and 3-year lung metastasis progression-free survival was 65% and 52%, respectively. We have demonstrated the feasibility of WLI using CS IMRT and confirmed the previously reported advantages of IMRT, including superior cardiac protection and superior dose coverage of 4D lung volumes. Further studies are required to establish the efficacy and safety of this irradiation technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.