Abstract

Cardiac tamponade during ablation procedures is a life-threatening complication. While the incidence and management of tamponade in atrial fibrillation ablation have been extensively described, the data on tamponade during ventricular ablations are very limited. The purpose of this study is to shed light on the incidence, typical perforation sites, and optimal management as observed through real-life data in a tertiary referral center for ventricular ablation. Consecutive patients with structural heart disease undergoing ventricular tachycardia ablation from 2008-2020 were analyzed. Of the 1078 patients undergoing 1287 ventricular ablation procedures, 20 procedures (1.5%) were complicated by cardiac tamponade. In all but one patient, the tamponade was treated with emergent pericardial drainage, while nine patients eventually underwent surgical repair. The perforation occurred during transseptal or subxiphoid puncture in six patients, during ventricle mapping in two patients, and during ablation in five patients (predominantly basal left ventricle). Steam pop as definite perforation cause could only be established in two patients. Regardless of the management of the complication, all patients survived to discharge. Cardiac tamponade during ventricular ablation occurred in 1.5% of the procedures. In nine patients cardiac repair was necessary. Perforation was mostly associated with subxiphoid puncture or ablation of the basal left ventricle.