Abstract

ObjectiveCarotid endarterectomy (CEA) is a preventive procedure aimed at decreasing the subsequent risk of fatal or disabling stroke in patients with significant carotid stenosis. It is well-known that carotid surgery under ultrasound-guided regional anesthesia (US-RA) causes a significant increase in blood pressure, heart rate and stress hormone levels owing to increased sympathetic activity. However, little is known about the effects on cardiac output (CO), cardiac index (CI), and cerebral blood flow (CBF) under US-RA as compared with general anesthesia (GA). MethodsPatients scheduled for CEA were randomized prospectively to receive US-RA (n = 37) or GA (n = 41). The primary end point was the change in CI after induction of anesthesia and the change from baseline over time at four different times during the entire procedure in the respective randomized US-RA and GA groups. In addition to systolic blood pressure and heart rate, we also recorded peak systolic velocity, end-diastolic velocity, and minimum diastolic velocity as seen from transcranial Doppler ultrasound examination, as well as regional cerebral oxygenation (rSO2) as seen from near-infrared refracted spectroscopy to evaluate cerebral blood flow. ResultsIn the US-RA group, the CI increased after induction of anesthesia (3.7 ± 0.8 L/min/m2) and remained constant until the end of the procedure. In the GA group CI was significantly lower (2.4 ± 0.6 L/min/m2; P < .001). After induction of anesthesia, the rSO2 remained constant in the GA group on both the ipsilateral (63 ± 9 rSO2) and the contralateral (65 ± 7 rSO2) sides; in contrast, it significantly increased in the US-RA group (ipsilateral 72 ± 8 rSO2; P < .001; contralateral 72 ± 6 rSO2; P < .001). The transcranial Doppler ultrasound parameters (peak systolic velocity, end-diastolic velocity, and minimum diastolic velocity) did not differ between the US-RA and the GA group. The clinical outcome was similarly favorable for both groups. ConclusionsCI was maintained near baseline values throughout the procedure during US-RA, whereas a significant decrease in CI values was observed during CEA under GA. Near-infrared refracted spectroscopy values, reflecting blood flow in small vessels, were higher in US-RA patients than in those with GA. These differences did not influence clinical outcome.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call