Abstract

We present the conventional cardiac magnetic resonance (CMR) protocol for evaluating a suspected thrombus and highlight emerging techniques.The appearance of a mass on certain magnetic resonance (MR) sequences can help differentiate a thrombus from competing diagnoses such as a tumor. T1 and T2 signal characteristics of a thrombus are related to the evolution of hemoglobin properties. A thrombus typically does not enhance following contrast administration, which also helps differentiation from a tumor. We also highlight the emerging role of T1 mapping in the evaluation of a thrombus, which can add another level of support in diagnosis. Prior to any CMR exam, patient screening and interviews are critical to ensure safety and to optimize patient comfort. Effective communication during the exam between the technologist and the patient promotes proper breath holding technique and higher quality images. Volumetric post processing and structured reporting are helpful to ensure that the radiologist answers the ordering services' question and communicates these results effectively. Optimal pre-MR safety evaluation, CMR exam execution, and post exam processing and reporting allow for delivery of high quality radiological service in the evaluation of a suspected cardiac thrombus.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call