Abstract

A healthy 31-year-old man who had previously sojourned to an altitude of 5,000 meters with no detrimental effect developed sudden cardiac asystole during a progressive hypoxic ventilatory response ( HVR ) test. At the moment of asystole, his alveolar PO2 (PAO2) was 41 mm Hg and his arterial oxygen saturation (SaO2) was 81 percent. Cardiopulmonary resuscitation was initiated, and after 20 seconds of asystole and apnea, he recovered normal sinus rhythm and spontaneous respiration. A subsequent ECG and cardiac enzyme levels were normal. During testing, he demonstrated depressed ventilation in response to hypoxia and a slowing of the heart rate. Careful observation of heart rate and breath-by-breath ventilation during HVR tests may predict this potentially fatal complication.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.