Abstract

For the proposed new heavy ion linac@GSI the installation of a carbon foil stripper section is under discussion. High duty factor as well as high current (but low duty factor) heavy ion beams were used for machine experiments. Long term tests were performed to check the carbon foil durability. Relevant beam parameters have been measured in three measurement campaigns. After beam testing stripper foils were analyzed with different offline methods. Additionally promising results of high current beam irradiation of rotating target wheels will be presented. In the transfer line to the SIS 18 the heavy ion beam is stripped to higher charge states in a thick carbon foil. The stripper foil is loaded with 3 % of the beam power. To avoid evaporation in a single beam pulse, the beam is rapidly swept over its width. Experiences collected during the last decade of foil stripper operation at GSI will be presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call