Abstract

We have irradiated several Allen Bradley carbon resistors (type BB, 1/8 W) at 4.6 K in a reactor up to a dose of 3 × 10 9 r gammas and 2.5 and 2.0 × 10 18 cm −2 thermal and fast neutrons respectively. A significant change of the R(T) characteristics is observed after irradiation and after subsequent annealing. For accurate temperature measurements allowance must be made for sufficient radioactivity decay time. A calibration procedure which is particularly suitable for high precision thermopower experiments is also reported.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.