Carbon molecular sieve (CMS) membranes on the inside of porous composite stainless steel supports were developed for gas separation in this research effort. The intermediate alumina layer was introduced to reduce the pore size of the porous stainless steel tube and subsequently provide uniform surface roughness. Viscosity of the phenolic polymer solution was varied from 10 to 30 centipoises (cP) to maximize performance of the CMS membranes. Pyrolysis temperature was also varied from 700 °C to 900 °C to optimize the fabrication of uniform CMS membranes on porous composite stainless steel supports. High performance CMS membranes were obtained from triple coatings and subsequent pyrolysis at 700 °C. The viscosity of precursor solutions played a critical role to determine the performance of CMS membranes in terms of gas permeance and ideal gas separation factor. The highest separation performance of the CMS membranes was shown with viscosity of 20 cP, resulting in gas separation factor of 462 for He/N2, 97 for CO2/N2, and 15.4 for O2/N2.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.