Abstract

Purpose: To describe the technique of carbon dioxide (CO2) flushing of thoracic stent-grafts to reduce the risk of cerebral air embolism. Technique: To remove room air, thoracic stent-grafts were preoperatively flushed 2 minutes with carbon dioxide from a cylinder connected to the flushing chamber of the captor valves of Zenith custom-made endografts; this was followed by the standard saline flush. Thirty-six patients undergoing thoracic endovascular aortic repairs (TEVAR) involving the ascending aorta and the aortic arch received CO2-flushed Zenith endografts. One patient with a highly calcified arch experienced a minor stroke. Conclusion: Arterial air embolism is a potentially underappreciated problem of aortic endografting, especially in the proximal segments of the aorta. CO2 flushing may have the potential to reduce air embolization during TEVAR.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.