Abstract
The aims of this study were: to compare indexes of the power and aerobic capacity, kinetics of O2 uptake and muscle power in two groups of middle-distance runners; to verify if the predicting performance is dependent of training level. Twenty-one male runners, nine classified as trained (group 1 – G1) and twelve moderately trained (group 2 - G2) performed the following tests: 1) time trial run in 1500-m; 2) maximal incremental test for determination of maximal oxygen uptake (VO2max), anaerobic threshold and running velocity at VO2max (vVO2max); 3) all-out exercise bout performed at vVO2max to determine time of support (Tlim) and the time to achieve VO2max (TAVO2max); 4) vertical jump. The main results showed that the power and aerobic capacity indexes were higher in G1, being able to differentiate the competitive level of the runners. The vVO2max explained the performance in 1500, regardless the training level.
Highlights
Na Tabela 2 estão apresentados os valores das variáveis obtidas no teste incremental (VO2max, velocidade correspondente ao VO2max (vVO2max), velocidade de corrida associada ao LAn (vLAn)), no teste de carga contínua (Tlim e parâmetros da cinética do VO2) e o desempenho no Counter Movement Jump (CMJ), indicador de potência muscular.Conforme os resultados mostrados na Tabela 2, os índices relacionados ao sistema aeróbio (VO2max, vVO2max, Tlim e vLAn) mostram-se significativamente superiores no grupo 1 (G1)
Poder-se-ia esperar que os corredores do G1 tivessem um menor Tau e TAVO2max que os atletas do grupo 2 (G2), pois está relatado que o efeito do treinamento aeróbio acelera a resposta do VO2 no início no exercício, alcançando o VO2max mais precocemente (DEMARLE et al, 2001); no entanto esta diferença parece ser perceptível somente quando comparados indivíduos com níveis de performance aeróbia bem diferentes, a exemplo dos achados de Caputo e Denadai (2004), que compararam atletas treinados com pessoas sedentárias
The aims of this study were: to compare indexes of the power and aerobic capacity, kinetics of O2 uptake and muscle power in two groups of middle-distance runners; to verify if the predicting performance is dependent of training level
Summary
RESUMO O estudo teve como objetivos comparar os índices de potência e capacidade aeróbia, cinética de consumo de O2 e potência muscular em dois grupos de corredores meio-fundistas e verificar se a predição da performance nos 1.500m é dependente do nível de treinamento. Diferentemente dos índices associados ao consumo de oxigênio (VO2), aqueles relacionados com a resposta do lactato sanguíneo, tais como o LAn, são os que melhor representam a capacidade aeróbia, demonstrando ter maior relação com o rendimento em provas de longa duração e ser capazes de selecionar o nível de performance, inclusive em atletas de elite (DENADAI, 1996), embora o LAn pareça não apresentar grande significância para o desempenho em provas realizadas entre 3 e 8 min, a exemplo dos 1,500 metros rasos (CAPUTO et al, 2009). Para a divisão dos grupos (G1 e G2), utilizou-se como critério seu nível competitivo
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have