Abstract

Efforts to prevent environmental pollution due to wastewater produced by car service station can be carried out using electrocoagulation technology. The purpose of this study was to analyze the effectiveness of electrocoagulation technology for treating car service station wastewater. This research is an experimental study conducted in a car workshop at PT Jaya Indah Motor Jambi City. The electrocoagulation machine used an Automatic PLC System WWTP 350 L with total dimensions of 1200 x 1200 x1700 mm, power 380Volt/20A (Stanby Steady State). Researchers compared the research data with the wastewater quality standards contained in the Ministry of Environment and Forestry Regulation No. P.68.MENLHK/Setjen/KUM/.I/8/2016. The results showed that the final value of the parameters of the treatment results using electrocoagulation had met the wastewater quality standards (TSS 19.75 mg/L; pH 6.92; BOD 8.46 mg/L; COD 25.07 mg/L; oil and fat 2.75 mg/L; and ammonia 7.12 mg/L).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.