Abstract

Accurate and reliable noninvasive methods to estimate gas exchange are necessary to guide clinical decisions to avoid frequent blood samples in children with pediatric acute respiratory distress syndrome (PARDS). We aimed to investigate the correlation and agreement between end-tidal measured immediately after a 3-s inspiratory-hold (PLAT CO2 ) by capnometry and measured by arterial blood gases (ABG) in PARDS. Prospective cohort study. Seven-bed Pediatric Intensive Care Unit, Hospital El Carmen de Maipú, Chile. Thirteen mechanically ventilated patients aged ≤15 years old undergoing neuromuscular blockade as part of management for PARDS. None. All patients were in volume-controlled ventilation mode. The regular end-tidal (without the inspiratory hold) was registered immediately after the ABG sample. An inspiratory-hold of 3 s was performed for lung mechanics measurements, recording in the breath following the inspiratory-hold. (PLAT CO2 ). End-tidal alveolar dead space fraction (AVDSf) was calculated as and its surrogate (S)AVDSf as . Measurements of were considered the gold standard. We performed concordance correlation coefficient (ρc), Spearman's correlation (rho), and Bland-Altmann's analysis (mean difference ± SD [limits of agreement, LoA]). Eleven patients were included, with a median (interquartile range) age of 5 (2-11) months. Tidal volume was 5.8 (5.7-6.3) mL/kg, PEEP 8 (6-8), driving pressure 10 (8-11), and plateau pressure 17 (17-19) cm H2 O. Forty-one paired measurements were analyzed. was higher than (52 mmHg [48-54] vs. 42 mmHg [38-45], p < 0.01), and there were no significant differences with PLAT CO2 (50 mmHg [46-55], p > 0.99). The concordance correlation coefficient and Spearman's correlation between and PLAT CO2 were robust (ρc = 0.80 [95% confidence interval [CI]: 0.67-0.90]; and rho = 0.80, p < 0.001.), and for were weak and strong (ρc = 0.27 [95% CI: 0.15-0.38]; and rho = 0.63, p < 0.01). The bias between PLAT CO2 and was -0.4 ± 3.5 mmHg (LoA -7.2 to 6.4), and between and was -8.5 ± 4.1 mmHg (LoA -16.6 to -0.5). The correlation between AVDSf and (S)AVDSf was moderate (rho = 0.55, p < 0.01), and the mean difference was -0.5 ± 5.6% (LoA -11.5 to 10.5). This pilot study showed the feasibility of measuring end-tidal CO2 after a 3-s end-inspiratory breath hole in pediatric patients undergoing controlled ventilation for ARDS. Encouraging preliminary results warrant further study of this technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.