Abstract

The determination of the antibiotic oxytetracycline (OTC), in pig tissues was investigated by capillary zone electrophoresis (CZE) with a prior solid-phase extraction (SPE) using alkyl-bonded silica and polymeric cartridges. The methodology developed allows determination of OTC in pig kidney, liver and muscle samples with detection limits below maximum residue limit values, and the procedures to extract OTC and clean-up the matrix are simple and reliable. The limit of detection for OTC was 160, 120 and 85 μg kg−1 for kidney, liver and muscle samples, respectively. The average recoveries from spiked samples (200 μg kg−1 and 1600 μg kg−1) were in excess of 63% with coefficients of variation between 2.0 and 9.8%. This method would be useful for routine monitoring of oxytetracycline residues in pig tissues.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.