Abstract

ABSTRACTThermal and hydrodynamic models were developed for an axial swallow-tailed micro-grooved heat pipe and solved numerically. The axial heat conduction, the variation of the axial meniscus radius and the thin liquid film heat transfer in the evaporator and condenser sections were included in the proposed model. The results showed that the liquid film thickness increases along the axial direction of the microgrooves. The evaporation heat transfer coefficient of the liquid-vapor interface in the evaporator section is greater than the condensation heat transfer coefficient of the liquid-vapor interface in the condenser section. Additionally, the evaporation/condensation mass flow rates in the adiabatic section are not all zero. The wall, liquid and vapor temperatures are almost the same in the adiabatic section. In addition, an experimental study was performed to verify the heat transfer model in a heat pipe with axially swallow-tailed microgrooves. Moreover, in this paper, the obtained numerical results are accordant with the obtained experimental data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.