Abstract
Abstract A capillary column gas chromatographic method is described for determining parts-per-trillion (ppt) levels of chlorsulfuron in agricultural runoff water. The water sample is acidified with acetic acid and extracted with methylene chloride. The chlorsulfuron in the extract is derivatized to its monomethyl derivative. After Florisil column cleanup, the methylated chlorsulfuron is determined by electron-capture gas chromatography. Recovery of chlorsulfuron from fortified water samples is greater than 80%. Detection limit of the method is 25 ng chlorsulfuron/L water (25 ppt). There are 2 reaction sites on the chlorsulfuron molecule, both of which are susceptible to methylation leading to monomethyl chlorsulfuron and dimethyl chlorsulfuron. A procedure is described to methylate selectively the sulfonamide nitrogen of chlorsulfuron.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.