Abstract

Valve Regulated Lead-Acid (VRLA) batteries can degrade due to a variety of mechanisms, including corrosion, hard sulfation, water loss, shedding, and active mass degradation. Hard sulfation can be the dominant aging mechanism for many cells. In this paper, pressure feedback is used to minimize water loss during low current charging designed to break up hard sulfate and recover capacity. A VRLA battery that was cycle tested to failure is used to test the desulfation charging control scheme. One cell of this battery that was diagnosed with sulfation degradation was desulfated for 313 hrs at an average current of 0.2 A. The capacity of the cell was recovered by 41% with minimal water loss, demonstrating the effectiveness of the desulfation charge controller.Copyright © 2012 by ASME

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.