Abstract

Most MMC distributed control systems require the central controller to collect capacitor voltages measured by local controllers to perform the phase average capacitor voltage control. Transmitting considerable capacitor voltages can greatly increase the communication burden in an MMC with numerous submodules. In this letter, we aim to significantly reduce the communication burden with adequate data exchange to maintain the control performance by proposing two round-robin transmission modes with voltage-ripple-filtering capability. The two transmission modes are elaborately designed to filter out specific harmonics for the removal of the low-pass filter in the voltage control loop. The feasibility of the capacitor voltage transmission modes is confirmed by the simulation and experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.