Abstract

The Z-source inverter (ZSI) is a recently proposed single-stage power conversion topology. It adds voltage boost capability for complementing the usual voltage buck operation of a traditional voltage source inverter (VSI) with improved reliability. In this paper, a single-loop and dual-loop capacitor voltage control techniques for the ZSI are digitally designed based on a third order small signal model of the ZSI, implemented using a digital signal processor (DSP) and compared. Simulation and experimental results of a 30 kW ZSI during input voltage changes, load disturbances and steady state operations are presented and compared. The results show that the dual-loop capacitor voltage control technique achieves better steady state and transient performance and enlarge the stability margins of the ZSI compared to the single-loop capacitor voltage control technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.