Abstract
The multiplexing scheme presented in this paper is part of the readout chain of the QUBIC instrument devoted to cosmic microwave background polarization observations. It is based on time domain multiplexing using superconducting quantum interference devices (SQUIDs) to read out a large array of superconducting bolometers. The originality of the multiplexer presented here lies in the use of capacitors for the SQUID addressing. Capacitive coupling allows us to bias many SQUIDs in parallel (in a 2D topology), with low crosstalk and low power dissipation of the cryogenic front-end readout. However, capacitors in series with the SQUID require a modification of the addressing strategy. This paper presents a bias reversal technique adopted to sequentially address the SQUIDs through capacitors using a cryogenic SiGe integrated circuit. We further present the different limitations of this technique and how to choose the proper capacitance for a given multiplexing frequency and current source compliance.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.