Abstract
The paper presents technical implementation of the electricalcapacitive method to perform in-process measurement of the capacitance per unit length of a single-core electric wire. The design of the electrocapacitive measuring transducer is proposed. The block diagram of the device CAP-10 developed to implement the proposed method is presented. The appearance of the device CAP-10 is showed, and its operating principle is described. It is shown that the change in water conductivity has a significant impact of the measurement result of the wire capacitance per unit length. The techniques to offset from the impact of water conductivity variation on measurement results are proposed. The technique of the device CAP-10 initial adjustment is proposed. It provides the desired function of the output signal transformation. The technique of the ‘operating’ adjustment to correct measurement results through systematic measurement error elimination is offered.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.