Abstract

This paper reports the development of a real-time inline Chemical Oxygen Demand (COD) detection technique in a beverage manufacturing plant in England and the evaluation of its capability for dynamic Water Footprint (WF) management. The inline technique employed Ultraviolet–Visible (UV-VIS) spectroscopy and Moving Window Partial Least Squares (mwPLS), which was then applied to calculating Grey WF for the production activities in the plant, referred to here as WFrt. A traditional offline COD measurement method was also utilised for the Grey WF calculation, to act as the reference method, referred to here as WFtrad. In a method-comparison study (Bland-Altman Plot), the results showed that WFrt detected the order of magnitude variation of WFtrad, and WFtrad was on average between 0.897 and 1.243 times WFrt with no systematic bias. This indicates that WFrt may be used for both short-time frame (minutes to hours) WF monitoring and long-term (weeks to months) analysis of trends and the effect of WF optimisation strategies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.