Abstract

Interest has focused on porous materials that promote bony ingrowth. In this study a porous tantalum implant was used as an adjunct to intercarpal stabilization in a canine model of wrist arthrodesis. A defect was created at the junction of the radiocarpal, ulnocarpal, and fourth carpal bones, analogous to a four-corner fusion site in humans. A tantalum cylinder was press-fit and stabilized with K-wires. Controls were represented by creating the defect without implant placement. Animals were killed at 4, 8, and 12 weeks. Histology showed bony ingrowth as early as 4 weeks and mechanical testing showed a statistically significant increase in strength of the construct over time. Controls failed to achieve union at any time point. The implant served as an adjunct to stabilization of the carpus in this model of four-corner fusion, suggesting a novel application of this material in conditions in which bone graft has been required previously. This study represents a preliminary investigation of the use of a tantalum device for intercarpal stabilization; it does not compare this technique with conventional methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.