Abstract

To create a replacement nasolacrimal system, using the puncta and canaliculi, with prolonged implant retention and minimal use of Elizabethan collars or other restraint devices. The method was used in 11 dogs and two cats. Silicone tubing was placed through both canaliculi and, via a drill hole, into the nasal cavity. Distally, the tubing ends were tied in a subcutaneous pocket lateral to the premaxilla. Tubing retention time was 4 to 7 months. Elizabethan collars were used only until skin suture removal at 2 weeks. In all animals, a functional nasolacrimal system was re-created and remained patent over prolonged follow-up periods. Adverse effects and complications were mild. The described method is relatively straightforward, thereby making relief of tear outflow problems widely accessible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.