Abstract

Evaluating the canal-centering and apical transportation ability of endodontic file systems working with different kinematics but of similar cross section. Sixty human maxillary first molar mesiobuccal (MB) roots were assigned to three experimental groups based on instrumentation techniques: Reciproc Blue (RB), Mtwo (M2), and OneShape (OS). Pre- and post-instrumentation micro-computed tomographic analysis was performed. Centering ability and apical transportation were analyzed at 3 mm, 6 mm, and 9 mm short of the apex. Statistical analysis was conducted using Mann-Whitney U test and Kruskal-Wallis test. OS showed better canal-centering ability than RB and M2 at 3 mm, 6 mm, and 9 mm. No significant difference among the tested groups was observed during the assessment of apical transportation (P < 0.05). The systems evaluated safely prepared curved MB canals with minimal canal transportation. OS showed superior canal-centering ability compared to the other two groups.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.