Abstract

Weighing lysimeters and neutron probes (NP) are both used to determine the change in soil water storage needed to solve for evapotranspiration (ET) using the soil water balance equation. We compared irrigated cotton ET determined using two large (3×3×2.4-m deep) weighing lysimeters and eight NP soil water profiles located outside the lysimeters in cotton fields during the BEAREX08 field campaign (see [16] Evett et al., 2012). The objectives were to (i) determine if lysimeter-based ET fluxes were representative of those from the fields, designated NE and SE, in which the lysimeters were centered, and (ii) investigate different methods of computing the soil water balance using NP data. Field fluxes were determined from the soil water balance using neutron probe measurements of change in profile water content storage. Fluxes of ET from the SE lysimeter were representative of those from the field throughout the season and can be used with reasonable certainty for comparisons of ET fluxes and energy balance closure derived from Bowen ratio (BR) and eddy covariance (EC) measurements whose footprints lay in the SE field. Comparisons of ET fluxes from EC and BR systems to those from the NE lysimeter should consider that NE lysimeter fluxes were up to 18% larger than those from the NE field during the period of rapid vegetative growth. This was due to plants on the lysimeter having greater height and width than those in the field. Nevertheless, the data from this and companion studies documents substantial underestimation of crop ET by EC stations under the conditions of BEAREX08. Comparison of zero flux plane (ZFP) and simple soil water balance methods of calculating ET from NP data showed them to be equivalent in this study; and for the ZFP method, the depth of the control volume should be determined by the depth at which the hydraulic gradient reverses, not by the depth of calculated minimum flux. If supported by a sufficiently dense and widespread network of deep soil water balance based estimates of ET in the surrounding patch and by ancillary measurements of crop stand and growth within the lysimeter and in the surrounding patch, a weighing lysimeter can provide accurate ET ground truth for comparisons with ET estimated using flux stations or ET calculated using satellite imagery. It must be emphasized that the water balance measurements must include soil profile water content measurements to well below (e.g., 0.5 to 1m below) the root zone in order to close the water balance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.