Abstract
The tolerance of the expected read-back signal of spin valve giant magnetoresistance based structures to varying deposition and process conditions are described. We determine if spin valves can be produced reliably, and evaluate which thicknesses and properties are most critical. First, the dependence of spin valve properties on layer thickness are experimentally determined. Next, the variation of read-back signal and transfer curve characteristics with spin valve properties is calculated from micromagnetic modeling. Finally, these are convolved with the expected reproducibility of layer thickness to obtain an effective “yield” of structures within 10% of the mean amplitude. We find that spin valves can be reliably deposited, with “yields” well in excess of 90% likely.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.