Abstract
Camera calibration is the important step for the stereo vision measurement system. The accuracy of the calibration affects the accuracy of the vision measurement system. The calibration is realized with a planar pattern. The pattern has some spot array with high precision. Stereo vision measurement system captures the images of the calibration pattern at several different orientations. The parameter model is modified as the polynomial model to describe the lens distortion. The calibration experiment demonstrates that the error of 3-D reconstruction is 0.020mm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.