Abstract

For traditional camera calibration methods, the calibration accuracy of camera parameters is highly dependent on the feature extraction of the control points of the calibration target. However, due to problems such as perspective and lens distortion, the commonly used checkerboards, circular dots, and other calibration patterns will inevitably undergo large deformation, resulting in a serious impact on the accuracy of the extraction of control points. To solve this problem, a camera calibration method based on active phase calibration targets is proposed. The method uses the MI Pad that can automatically display the structured light patterns as the calibration target. Compared with the method of using a checkerboard calibration target, this method does not require pattern detection and avoids the process of manual marking. Also, based on the phase information of the structured light gratings, a large number of dense, high-precision control point coordinates can be obtained even in areas where the image edge distortion is severe. Not only is it highly automated, but it is also suitable for defocused cameras. Experimental results show that the reprojection error of our method is only onetenth of the comparison method, and it has better robustness and accuracy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.