Abstract

The CMD-3 detector has been collecting data since 2010 at the e+e− collider VEPP-2000 in the Budker Institute of Nuclear Physics. VEPP-2000 uses the novel round beam technique and provides high luminosity in a wide c.m.energy range from 0.32 to 2 GeV. The physics goal of the CMD-3 experiment is a study of the e+e− annihilation into hadrons. CMD-3 is a general-purpose detector, which provides high efficiency for both charged and neutral particles. The electromagnetic calorimeter consists of the barrel calorimeter based on liquid xenon and CsI crystals, and the endcap calorimeter based on BGO crystals. The main parameters of the calorimeters are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.