Abstract

However, doctors do have an earlier chance to intervene. By implanting a specialized device into a person's chest, they can equip the heart to recover instantly when death comes knocking. When the electrical leads of these so-called implantable cardioverter-defibrillators, or ICDs, detect an abnormal heart the attached pager-size generator delivers a shock that restores the normal cadence. Use of these devices began in the 1980s and has increased exponentially in recent years. This year, U.S. doctors will surgically implant some 200,000 defibrillators at a cost of about $30,000 to $50,000 per operation. Yet most of the devices will never see action. About four-fifths of defibrillators sit quietly in people's chests until their batteries conk out. Replacing a battery, which is necessary every 5 years or so, requires another round of surgery. Defibrillators also can be cantankerous. They sometimes mistake mild arrhythmia, or rhythm disruption, for a deadly spasm and shock the heart unnecessarily, causing pain but no permanent harm. And while some people die because a device fails to fire when it should-a problem that spawned massive recalls of certain models last year-many more perish because no one recognized that a defibrillator could have saved their lives. would like to improve their ability to distinguish people who truly need defibrillators from those who don't. current method uses a crude measure: the heart's mechanical efficiency at pumping blood. That value, called ejection fraction, has no direct relationship with the heart's electrical circuitry. Recent studies suggest that measures of the heart's electrical function and its responsiveness to the nervous system may reveal additional information about the heart's vulnerability to arrhythmia. Medical researchers recently concluded the first systematic test in which they weighed one such promising factor-an electrical characteristic called T-wave alternans-for deciding who should a defibrillator. They plan to announce their results at a medical meeting this November. If such trials prove that T-wave altemans and other new measures can supplement ejection fraction in clinical evaluation of patients, doctors may save more lives even though they implant fewer devices than they do now. HIGH PRICE AT THE PUMP With each contraction of the the organ's left ventricle squeezes blood into the body's arteries. A healthy chamber pumps out half to three-quarters of its contents, while a defective heart might expel 30 percent or less. This ejection fraction, expressed on a 100-point scale, can be gauged painlessly by performing a sonogram of the chest. An insult such as a myocardial infarction-commonly called a heart attack-causes muscle damage that can instantly trigger fatal arrhythmia, or it can permanently reduce ejection fraction. same muscle damage can also interfere with the conduction of electrical impulses through the thereby increasing the chance that a subsequent life-threatening arrhythmia will occur. Ejection fraction has been studied extensively and is clearly associated closely with sudden death, says cardiac electrophysiologist David S. Rosenbaum of Case Western Reserve University's MetroHealth Campus in Cleveland. form of arrhythmia that usually triggers cardiac arrest is called ventricular fibrillation. In that event, uncoordinated muscle contractions cause the ventricles to flutter ineffectuallv. malfunction develops when electrical impulses that control the pace and rhythm of the ventricles' contractions become irregular. The lethal event is electrical-a catastrophic disturbance in rhythm, says Richard Verrier, a cardiovascular electrophysiologist at Beth Israel Deaconess Medical Center in Boston. That's precisely the problem that defibrillators are designed to solve. People with an ejection fraction lower than 30 have been shown to benefit from defibrillators, so physicians currently use thatvalue as athrueshold when deciding who should a device. With that cut-off and other criteria, such as previous ventricular fibrillation or advanced heart failure, about 1.6 million people in the United States are eligible, according to Minneapolis-based device maker Medtronic. Yet ejection fraction reveals limited information about the heart's electrical integrity. You can have a lethal disturbance without having any [preexisting physical] damage to the heart, Verrier notes. Or, the organ can have damage that never leads to an arrhythtia. You're using a measure of mechanical abnormality to predict an electrical event, so you can't expect it to be overwhelmingly accurate; says Rosenbaum. Doctors have to implant 17 defibrillators to save one person. benefit is real, but it's modest and has to be weighed against the risk.' Hazards of the surgery include infections, clots, and internal bleeding. And when devices fire unnecessarily, patients get a flurry of shocks, says cardiologistJ. Thomas Bigger Jr. of Columbia University's New York-Presbyterian Hospital. The lethal event is electrical-a catastrophic disturbance in rhythm.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call