Abstract

A 'round robin' exercise was carried out by the UK SPATE users' group to determine factors affecting the calibration of SPATE equipments. The participants separately measured, using their own SPATE equipments and calibration techniques on identical materials, SPATE output per unit range of principal stress sum. Even after known differences in factors such as system responsivity or test temperature have been allowed for, there is a considerable scatter (of the order of 20%) in the results obtained. The cause of this is not yet known. This variation causes SPATE calibration using material properties to be less reliable than calibration by 'known stress' methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.