Abstract
Liquid lead-bismuth eutectic (LBE) may see extensive use as a coolant fluid, and perhaps also as a spallation target, in the next generation nuclear energy system. However, it is very corrosive to the common steels used in nuclear installations. This corrosion problem can be prevented by the formation of a protective oxide layer on the exposed surface of steel. For this purpose, accurately measuring and controlling the oxygen concentration in liquid LBE is very important. Electrochemical oxygen sensors with In/In 2O3 and Bi/Bi 2O3 reference systems can be used as in situ devices for measuring the oxygen concentration in liquid LBE. YSZ (Yttria Stabilized Zirconia) oxygen sensor with molten bismuth saturated with oxygen as a reference, has been selected to measure the oxygen concentration in LBE coolant system. The oxygen concentration difference across the solid electrolyte and the resultant oxygen ion conduction inside the electrolyte establish an electromagnetic force (EMF) that is used to measure the ppb level of dissolved oxygen concentration in liquid LBE. In this paper, the sensitivity of an YSZ oxygen sensor has been evaluated. Sensor calibration curves in liquid LBE at 450 o C have been obtained.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.