Abstract

An integrative passive sampler consisting of a C 18 Empore ® disk receiving phase saturated with n-octanol and fitted with low-density polyethylene diffusion membrane was calibrated for the measurement of time-weighted average concentrations of hydrophobic micropollutants, including polyaromatic hydrocarbons and organochlorine pesticides, in water. The effect of temperature and water turbulence on kinetic and thermodynamic parameters characterising the exchange of analytes between the sampler and water was studied in a flow-through system under controlled conditions. It was found that the absorption of test analytes from water to the sampler is related to their desorption to water. This allows for the in situ calibration of the uptake of pollutants using offload kinetics of performance reference compounds. The sampling kinetics are dependent on temperature, and for most of the tested analytes also on the flow velocity. Sampler–water partition coefficients did not significantly change with temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.