Abstract

AbstractThe time‐interleaved analog‐to‐digital converter (TIADC) system could achieve high sampling rate effectively, but the frequency response inconsistency among channels will introduce frequency response mismatches, which will seriously degrade the signal quality. In this paper, a novel multi‐channel frequency response mismatches adaptive calibration method is proposed. The frequency response of the compensation filter is expanded into a polynomial of a digital differentiator, and the least mean square adaptive strategy is used to calibrate frequency response mismatches. It does not require measuring the channel frequency responses in advance and uses digital post‐processing technology to effectively compensate the frequency response of the multi‐channel TIADC system and improve the spurious‐free dynamic range. The experimental results verify the effectiveness of the algorithm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call