Abstract

We have developed focal plan array (FPA) imagers based on very inexpensive miniature neon indicator lamp detectors called glow discharged detectors (GDDs). The novelty of this paper is a technique of calibration, which permits reliable imaging with such an inexpensive FPA. GDDs are commercial lamps, which lack uniformity as detectors. The technique developed in this paper cancels out differences in response between the FPA lamps caused by both nonuniformity of the MMW collimated beam, and nonuniformity of the GDDs and other components in the electronic circuit. Utilizing this method in the new imaging system unifies detector response. Results, shown with two types of sensor configurations (8 × 8 and 18 × 2 scanner array), indeed show better performances and improvement in visibility of details.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.