Abstract

A calibration-free scanned wavelength modulation spectroscopy scheme requiring minimal laser characterization is presented. Species concentration and temperature are retrieved simultaneously from a single fit to a group of 2f/1f-WMS lineshapes acquired in one laser scan. The fitting algorithm includes a novel method to obtain the phase shift between laser intensity and wavelength modulation, and allows for a wavelength-dependent modulation amplitude. The scheme is demonstrated by detection of H(2)O concentration and temperature in atmospheric, premixed CH(4)/air flat flames using a sensor operating near 1.4 µm. The detection sensitivity for H(2)O at 2000 K was 4 × 10(-5) cm(-1) Hz(-1/2), and temperature was determined with a precision of 10 K and absolute accuracy of ~50 K. A parametric study of the dependence of H(2)O and temperature on distance to the burner and total fuel mass flow rate shows good agreement with 1D simulations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.