Abstract

Context.NIKA2 is a dual-band millimetre continuum camera of 2 900 kinetic inductance detectors, operating at 150 and 260 GHz, installed at the IRAM 30-m telescope in Spain. Open to the scientific community since October 2017, NIKA2 will provide key observations for the next decade to address a wide range of open questions in astrophysics and cosmology.Aims.Our aim is to present the calibration method and the performance assessment of NIKA2 after one year of observation.Methods.We used a large data set acquired between January 2017 and February 2018 including observations of primary and secondary calibrators and faint sources that span the whole range of observing elevations and atmospheric conditions encountered by the IRAM 30-m telescope. This allowed us to test the stability of the performance parameters against time evolution and observing conditions. We describe a standard calibration method, referred to as the “Baseline” method, to translate raw data into flux density measurements. This includes the determination of the detector positions in the sky, the selection of the detectors, the measurement of the beam pattern, the estimation of the atmospheric opacity, the calibration of absolute flux density scale, the flat fielding, and the photometry. We assessed the robustness of the performance results using the Baseline method against systematic effects by comparing results using alternative methods.Results.We report an instantaneous field of view of 6.5′ in diameter, filled with an average fraction of 84%, and 90% of valid detectors at 150 and 260 GHz, respectively. The beam pattern is characterised by a FWHM of 17.6″ ± 0.1″ and 11.1″ ± 0.2″, and a main-beam efficiency of 47%±3%, and 64%±3% at 150 and 260 GHz, respectively. The point-source rms calibration uncertainties are about 3% at 150 GHz and 6% at 260 GHz. This demonstrates the accuracy of the methods that we deployed to correct for atmospheric attenuation. The absolute calibration uncertainties are of 5%, and the systematic calibration uncertainties evaluated at the IRAM 30-m reference Winter observing conditions are below 1% in both channels. The noise equivalent flux density at 150 and 260 GHz are of 9 ± 1 mJy s1/2and 30 ± 3 mJy s1/2. This state-of-the-art performance confers NIKA2 with mapping speeds of 1388 ± 174 and 111 ± 11 arcmin2mJy−2h−1at 150 and 260 GHz.Conclusions.With these unique capabilities of fast dual-band mapping at high (better that 18″) angular resolution, NIKA2 is providing an unprecedented view of the millimetre Universe.

Highlights

  • The NIKA2 instrument was installed at the IRAM 30-m telescope in October 2015 with partial readout electronics, and it has operated in the final instrumental configuration since January 2017

  • We found 840, 868, and 508 kinetic inductance detector (KID) using this definition for Array 1 (A1), Array 3 (A3), and Array 2 (A2), respectively

  • Atmospheric opacity estimation We developed three procedures for the atmospheric opacity derivation: (i) taumeter relies on measurements provided by the resident IRAM taumeter operated at 225 GHz; (ii) skydip consists of using NIKA2 as a total-power taumeter by resorting to a series of skydip scans; (iii) corrected skydip is a modified version of the skydip method that minimises the dependence of the estimated flux density on the opacity

Read more

Summary

Introduction

Ground-based continuum millimetre experiments have made spectacular progress in the past-two decades thanks to the advent of large arrays of high-sensitivity detectors (Wilson et al 2008; Siringo et al 2009; Staguhn et al 2011; Swetz et al 2011; Monfardini et al 2011; Arnold et al 2012; Bleem et al 2012; Holland et al 2013; Dicker et al 2014; BICEP2 Collaboration et al 2015; Adam et al 2017a; Kang et al 2018) This fast growth will continue as experimental efforts are driven by two challenges: improving the sensitivity to polarisation to detect the signature of the end-of-inflation gravitational waves in the CMB, and improving the angular resolution.

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.