Abstract

The integration and calibration of a narrow-band imaging po- larimeter is described. The system is designed to exploit subtle spectral details in visible and near-IR polarimetric images. All of the system components were commercial off the shelf. This device uses a tunable liquid crystal filter and a 16-bit cooled CCD camera. The challenges of calibrating a narrow-band imaging polarimeter are discussed. We describe examples of image data collected in the laboratory, which show that spectral polarimetric data is superior to unpolarized intensity data in facilitating the extraction of detail in shadowed regions below a vegetative canopy. In particular, we introduce a polarization-based normalized difference vegetation index (NDVI) algorithm that demonstrates significant contrast enhancement between a man-made object and a foilage background.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.